JBOD Components
-
One (1) EonStor 3U JBOD enclosure
-
One (1) JBOD controller module
-
One (1) 128MB SDRAM DIMM module (pre-installed on the controller module)
-
Two (2), hot-swappable, redundant, 460W power supply units
-
Two (2), hot-swappable, redundant, dual-fan, cooling modules
-
Sixteen (16), hot-swappable, drive trays
-
Two (2) front handles
Management
-
Module status LED indicators
-
Two (2) per drive tray
-
Two (2) per cooling module
-
One (1) per power supply unit
-
Nine (9) per JBOD controller module
-
Onboard alarm is triggered when one of the following modules fails:
-
JBOD controller module
-
Cooling modules
-
Power supply unit
-
Hard drive
-
Serial port communication with PC hyper-terminal
Host/Drive Interface
-
Supports 3.5", 1" high hard disk drives
-
Sixteen (16) hot-swappable drive trays
-
Single dual loop across 16 drives within enclosure
-
Auto-negotiate and full-duplex 2Gb FC-AL
Physical/Electrical
Interfaces:
-
Four (4) SFP sockets that use short-wavelength adapters
-
One (1) RS-232C (Audio Jack) serial port (38400, n, 8, 1) for diagnosis only
Power Supply Unit (PSU) modules
-
Two (2) redundant, hot-swappable, 460W, PSU modules with PFC.
INPUT: |
90 ~ 260VAC |
|
47 ~ 63MHz |
|
OUTPUT: |
(Maximum output: 460 Watts) |
+12.0V |
32A max. |
+5.0V |
25A max. |
+ 3.3V |
20A max. |
Cooling fan
Two (2), redundant, hot-swappable, dual-fan, cooling modules.
Fan speed: |
3600rpm |
Fan size: |
9.7cm |
Airflow per cooling module: |
61 CFM 460 Watts) |
Environmental Specifications
Operating temperature: |
5 to 40° C |
Non-operating temperature: |
- 40º to 60ºC |
Relative humidity: |
10 to 95%, non-condensing |
Operating altitude: |
sea level to 10,000ft |
Dimensions:
-
Without protrusions: 131H x 446.2W x 500D mm
-
With protrusions: 131H x 485W x 532D mm
-
Package dimensions: 476H x 592W x 695D mm
System weight (w/o drives):
-
Net weight:20kg
-
Gross weight: 32kg