• Highlights
  • Specifications
  • Accessories
  1. Two (2) SCSI-320 host channels; transfer rate up to 320MBps per channel.
  2. RoHS-compliant
  3. Accommodates sixteen (16), 3Gbps, SATA-II (3Gbps) disk drives.
  4. ASIC400 architecture with hardware RAID6.
  5. Market leading I/O performance
    1. Sustained RAID5 Read/Write at 566/484 MB/sec.
    2. Sustained RAID6 Read/Write at 566/426 MB/sec.
  6. Up to 1GB DDR memory, ECC protected.
  7. Hot-swappable, life expectancy-aware battery backup.
  8. Online expansion, array roaming, and centralized management.
Host-to-Drive Interface Configuration Model Form Factor
SCSI-320 to SATA-II (3Gbps) Single A16U-G2430 3U Rackmount
RAID
  1. Multiple arrays each with an independent RAID level
  2. Dedicated, enclosure-specific, or global hot spares.
  3. RAID levels: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
  4. Online RAID level migration
  5. Online expansion by:
    1. Adding new drives
    2. Copying and replacing drives with drives of larger capacity
  6. Automatic background rebuilds.
  7. Independent array stripe size and write policy
  8. Intelligent drive handling:
    1. Degraded mode: skips irreparable blocks to continue rebuild
    2. Normal: data-block verification and repair
Subsystem Components
  1. Backplane-based, cableless design
  2. Single-controller configuration provides full-range RAID functionalities
  3. Two (2) hot-swappable, redundant, 530W power supply units (PSUs)
  4. Two (2) redundant, dual thermal fans, cooling modules.
  5. One (1) optional BBU
    1. Sixteen (16) hot-swappable drive trays
    2. LCD keypad panel
Infortrend Smart Technologies
IOSmart
  1. Multiple, co-existing logical drives, logical volumes, and logical partitions
  2. Instant RAID availability via background initialization.
  3. Multi-path load balancing
  4. Streaming I/O Optimization by outstanding I/Os
  5. Adaptive Write Policy and Guaranteed Latency I/O
    1. Intelligent switch between caching modes
    2. Non-staggering data flow for bandwidth-oriented applications
DrvSmart
  1. Media Scan: manual or scheduled scans to repair data from hard drive media errors
  2. Disk Cloning, Copy & Replace, Drive Roaming
  3. SMART support, transparent resetting of non-responsive hard drives
  4. RAID parity update tracking and recovery
SysSmart
  1. Event-triggered operation: raises fan speed and adopts conservative caching policy in degraded mode

  2. Real-time monitoring of component statuses, voltage, and temperature readings
  3. Various methods to save/retrieve configuration profile and system events
  4. Battery life expectancy aware
Host Interface
  1. Two (2) SCSI-320 host channels; multiple SCSI IDs and LUNs
  2. Interfaced through four (4) VHDCI's (for host and cascading)
  3. Concurrent I/O commands
  4. Tagged command queuing up to 256
Drive Interface
  1. Sixteen (16) hot-swappable 3Gbps SATA-II (3Gbps) drive trays
  2. NCQ and S.M.A.R.T. support
  3. Dedicated bandwidth to each connected drive
Management
  1. Firmware-embedded utility via LCD keypad or RS-232 serial port
  2. VT-100 terminal emulation via RS-232C
  3. Telnet access via Ethernet port
  4. 10/100 BaseT Ethernet for out-of-band management
  5. Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
  6. Java-based SANWatch software:
    1. Graphical user interface
    2. Local/remote management; in-band or out-of-band via TCP/IP
    3. Centralized management to monitor and administer multiple RAID units on one screen
    4. Secure link over SSL
  7. Configuration Client as an independent software for event notification
  8. Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
Indicators
  1. Onboard alarm
  2. Module status LED indicators:
  3. Module monitoring through I2C bus
  4. Event notifications via Email, fax, LAN broadcast, SNMP traps, MSN messenger, and SMS short messages
  5. Real-time monitoring via RAIDWatch manager

Physical/Electrical

Interfaces
  1. Four (4) VHDCI SCSI ports (for host and cascading)
  2. Two (2) COM ports for RS-232C terminal and UPS support
  3. One (1) 10/100BaseT Ethernet port
Power Supply Module

Two (2) redundant, hot-swappable power supplies with PFC

Input 100VAC at 9A, 240 VAC at 4.5A with PFC (auto-switching)
47 to 63Hz
Output (Maximum output: 530 Watts)
+12.0V 32A max.
+ 5.0V 32A max.
+ 3.3V 30A max.
Cooling Module

Two (2) redundant, dual-fan cooling modules

Maximum Air Flow High speed: 90 DFM
Low speed: 70.7 CFM
Environmental Specifications
Temperature: Operating: 0° to 40°C (32° F to 104° F) (without BBU)
Operating: 0° to 35°C (32° F to 95 ° F) (with BBU)
Non-operating: - 40° to 60°C (-40° F to 140° F)
Relative humidity: Operating: 10% to 80% (non condensing)
Non-operating: 10 to 95% (non condensing)
Altitude: Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft
Dimensions:
  1. Chassis without handles: 445(W) x 130(H) x 486.7(D) mm (17.5 x 5.1 x 19.2 inches)
  2. Chassis with handles: 482.6(W) x 131(H) x 534.6(D) mm (19 x 5.2 x 21 inches)
  3. Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System weight (w/o drives):
  1. Net weight: 28.5kg (62.7 pounds)
  2. Gross weight: 30.5kg (67.1)

Spare Parts

IFT-9373CDTray 3.5" Hard disk drive tray
IFT-9273ECPSU Power supply module, for ES Enhanced 3U/16-bay subsystems, 530W capacity, Axial-FAN
IFT-9273ECFanMod Cooling fan module, for ES Enhanced 3U/16-bay subsystems, Axial FAN
IFT-9270CHandR Right-side forearm handle, for ES 3U/16-bay subsystems, applicable to the Left or Right-side of JBOD subsystems
IFT-9273CHandLLCD Left-side forearm handle, for ES Enhanced 3U/16-bay subsystems, LCD panel included
IFT-83AU24GE16 SCSI to SATA RAID controller module, for ES A16U-G2430 subsystem, 4 x SCSI-320 VHDCI host connectors.
IFT-9011 Null Modem, DB9 female to DB9 male, wires swapped
IFT-9270UJBODCAB SCSI external round cable, VHDCI to VHDCI
IFT-9270ASCab RS-232C serial cable, audio-jack to DB9
IFT-DDRESCM2 256MB DDR DIM module for all EonStor subsystems

Accessories

IFT-9273CBTE Battery cell pack, Li-Ion, for ES Enhanced 3U/16-bay subsystems, BBU ID
IFT-9270UHSTCAB SCSI external round cable, DB68 to VHDCI
IFT-9270CUPSCab UPS cable, audio-jack to DB9
IFT-9273CSlider32 Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~32" rack depth
IFT-9273CSlider36 Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~36" rack depth
IFT-DDRESCEM5 512MB DDR DIM module for all EonStor subsystems
IFT-DDRESCEMA 1GB DDR DIM module for all EonStor subsystems