Specifications

RAID
  1. Multiple arrays configurable with dedicated or global hot spares
  2. Supports RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
  3. Infortrend Smart Technologies
    1. IOSmart Technology
    2. DrvSmart Technology
    3. SysSmart Technology
System Components
  1. Redundant, hot-swappable components , designed for no single point of failure
    1. One (1) EonStor enhanced 3U enclosure
    2. Sixteen (16) hot-swappable drive trays
    3. Two (2) front handles
    4. One (1) RAID controller module in the F16F-S2021 or two (2) in the F16F-R2021
    5. 512MB DDR RAM DIMM module pre-installed on each RAID controller
    6. One (1) independent battery backup unit (BBU) in the F16F-S2021 or two (2) in the F16F-R2021
    7. Two (2) hot-swappable, redundant, 460W power supply units (PSUs)
    8. Two (2) hot-swappable, redundant cooling modules each with two (2) dual-speed fans
    9. One (1) enclosure configuration card
    10. Two (2) host connection modules
    11. Two (2) drive loop expansion module
Host Interface
  1. Up to four (4) FC-2G host channels with bypass circuit embedded to eight (8) FC ports on separate I/O modules
  2. DIP switch and jumper switch settings to change host port attributes
  3. Auto-negotiate FC-AL, point-to-point, or switched fabric
  4. Concurrent I/O commands
  5. Tagged command queuing up to 256
  6. Variable stripe size per logical drive
  7. Optimization setting for random or sequential I/Os
Drive Interface
  1. Up to four (4) FC-2G drive channels with bypass circuit embedded to eight (8) FC ports on two (2) separate drive loop expansion modules
  2. Sixteen (16) hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch Fibre disk drives
  3. Single dual-loop across sixteen (16) drives
  4. Automatic bad-sector reassignment
  5. Dedicated bandwidth to each connected drive
Management
  1. Firmware-embedded utility via LCD keypad or RS-232C port
  2. Host-side SES emulation with pass-through to back-end SES emulation
  3. 10/100 BaseT Ethernet for out-of-band management
  4. Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
  5. Java-based RAIDWatch® Manager:
    1. VT-100 terminal emulation via RS232 serial port
    2. Telnet access via onboard Ethernet port
    3. Cross-platform, remote administration with SSL
    4. Out-of-band access via Ethernet
    5. Centralized management to monitor and administer multiple RAID units on one screen
  6. Configuration Client for easy access to the configuration utility screen
  7. SNMP 2.0 MIBs with get and set commands
SAN Management
  1. Up to 1024 LUNs (if sufficiently large memory is used with the proper settings)
Indicators
  1. Onboard alarm is triggered when one of the following fails:
    1. RAID controller module
    2. Cooling module
    3. Power supply unit
    4. Hard drive
    5. BBU module
    6. Host connection module
    7. Drive loop expansion module
  2. Module status LED indicators:
    1. Three (3) per LCD panel
    2. Two (2) per drive tray
    3. Six (6) per RAID controller module
    4. Two (2) per Ethernet port
    5. One (1) per BBU module
    6. Two (2) per cooling module
    7. One (1) per PSU
    8. One (1) per Fibre port on host connection module and drive loop expansion module
  3. Module failure alert through I²C bus
  4. Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, SMS short messages
  5. System alerts through Java-based RAIDWatch Manager

Infortrend Smart Technologies

Derived from more than ten years experience in RAID storage design, Infortrend’s innovative firmware delivers Smart technologies that provide enhanced storage solutions for every customer environment, from small organizations to large enterprises. These technologies enhance I/O processing, drive handling, and system management.

IOSmart

IOSmart allows for the flexible configuration of logical drives, logical volumes and logical partitions and ensures instant RAID availability via background logical drive initialization. Fibre loops’ load balancing is provided within the subsystem. The firmware’s embedded intelligent algorithms, such as Adaptive Write Policy and Guaranteed Latency I/O, improve sequential write performance and ensure the fast and continuous flow of data.

DrvSmart

The DrvSmart utility provides an easy way to store data while keeping it safe. One of the main DrvSmart functions, Media Scan, retrieves data from degraded or damaged hard drives and handles low quality drives in both the degraded mode and during the rebuild process. Other DrvSmart features include disk cloning, drive roaming, SMART, transparent resetting of non-responsive hard drives, and RAID parity update tracking and recovery.

SysSmart

In addition to RAID protection for the disk drives, Infortrend has introduced Auto Data Protection Mechanisms. These special SysSmart firmware functions ensure data safety by automatically switching to write-through data caching when abnormal subsystem conditions are detected such as a PSU/cooling module failure, low BBU or UPS battery charge, etc.

By using the firmware to monitor and control the enclosure’s dual-speed fans, the fan rotation speed is raised to a higher level when critical conditions are detected, e.g., a PSU or fan failure. Fan speed returns to the lower setting when normal operating status is restored.

Physical/Electrical

Interfaces:
  1. Twelve (12) FC ports, each using a short-wavelength adapter
  2. Two (2) COM ports on each controller module for RS-232C serial port (38400, n, 8, 1) and UPS support
  3. One (1) 10/100BaseT Ethernet port on each controller module
Power Supply Module

Two (2) redundant, hot-swappable power supplies with PFC

Input 100VAC at 10A, 240 VAC at 5A with PFC (auto-switching)
47 to 63Hz
Output Maximum output: 460 Watts
+12.0V 32A max.
+ 5.0V 32A max.
+ 3.3V 30A max.
Dimensions 248.9(D) x 128(W) x 82.1(H) mm (9.8 x 5 x 3.2 inches)
Cooling Module

Two (2) redundant, dual-fan cooling modules

Maximum Air Flow High speed: 31.8 DFM
Low speed: 20.1 CFM
Environmental Specifications
Operating Temperature 0° to 40°C
Non-operating Temperature -40° to 60°C
Relative Humidity 5 to 95%, non-condensing
Altitude Operating: 0 to 12,000 ft
Non-operating: 0 to 40,000 ft
Dimensions:
  1. Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
  2. Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches)
  3. Shipping box: 567(W) x 423(H) x 772(D) mm (22.3 x 16.7 x 30.4 inches)
System weight (w/o drives):
  1. Net weight: 28.5kg (62.7 pounds)
  2. Gross weight: 30.5kg (67.1 pounds)