F16F-S2A2
- FC-to-FC RAID Subsystem
- Highest density, 16 drives in 3U rack space
- Auto switch cache policy and Auto shutdown
- Compliant with networked storage software and clustering supporting transparent failover
- Up to 64TB capacity per Logical Drive (LD) (OS dependent)
Configuration | Model | Form Factor |
---|---|---|
Single | F16F-S2A2 | 3U Rackmount |
Redundant | F16F-R2A2 | 3U Rackmount |
Redundant | F16F-R2A2-A | 3U Rackmount |
Specifications
RAID
- Multiple arrays configurable with dedicated or global hot spares
- RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
-
Online expansion by
- Adding new drives
- Copying and replacing drives with drives of larger capacity
- Automatic background rebuild
- Configurable stripe size and write policy per array
-
Intelligent Drive Handling
- In degraded mode: Skipping irreparable blocks to continue rebuild
- In normal operation: Data block verification and repair
System Components
Redundant, hot-swappable components, designed for no single point of failure
- 3U RAID enclosure or JBOD
- Single or dual redundant RAID controllers
- 16 drive trays
- Dual redundant power supplies
- 2 hot-swappable fan modules
- 2 hot-swappable expansion port modules
Management
- Firmware-embedded Java-based GUI RAID manager
- Centralized management of multiple arrays over in-band or Ethernet
- Real-time event notification over Email, LAN broadcast, or SNMP traps
- Auto on-lining of cascaded enclosures
- SES modules on JBODs
- SNMP 2.0 MIBs with get and set commands
- Firmware-embedded utility via LCD keypad or RS-232C port
Drive Interface
- Up to 1024 LUNs if sufficiently large memory is used with the proper settings
- 3.5", 1" high disk drives
- 16 hot-swappable drive trays
- Automatic bad sector reassignment
- Drive hot-swappable via SCA-II connectors
- Dual channels across 16 drives within each enclosure
Host Interface
- Auto-negotiate FC-AL, point-to-point, and switched fabric
- Concurrent I/O commands
- Tagged Command queuing up to 256
- Variable stripe size per logical drive
- Optimization setting for random or sequential I/Os
Maintenance & Availability
- Firmware rolling upgrade on redundant RAID controllers
-
Synchronized cache over
- R2A2: over shared drive loops
- R2A2-A: over dedicated communications loops
- Li-ion battery support, comes standard with R2A2/R2A2-A
- Immediate array availability
- Drive roaming, array configuration on drives
- Auto switch cache policy and Auto shutdown
When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
- Automatically flush cached data and switch the array’s caching mode from write-back to write-through
- Commence an auto shutdown
What is remarkable is all environmental thresholds associated with this mechanism are user-configurable and that caching mode changes back to write-back once normal condition is restored.
Physical/Electrical
Interfaces
4 (JBOD), 6 (single controller), or 8 (dual controllers) SFP sockets using a short-wavelength adapter, one DB-9 RS-232C serial port (38400, n, 8, 1), and RJ-45 Ethernet port
Power supply
- 2 redundant, hot-swappable power supplies with PFC
- Input: 90~260VAC, 47~63Hz
- Output: +5V, 25A max.; +12V, 32A max.; +3.3V, 20A max.; 460watts capacity
Cooling fan
- 4 cooling fans in two separate modules
- Operating temperature: 5 to 40°C
- Non-operating temperature: - 40º to 60ºC
- Relative humidity: 10~95%, non-condensing
- Operating altitude: sea level to 10,000ft
Dimensions
- Chassis dimensions: 131H x 446.2W x 500D mm
- (w/ protrusions): 131H x 485W x 532D mm
- Package dimensions: 476H x 592W x 695D mm
System weight (w/o drives):
- Net weight: 20kg
- Gross weight: 32kg