RAID Controller
-
Hardware RAID engine
-
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
-
RAID Migration
-
Configurable stripe size and write policy per array
-
Multiple Global, Dedicated, & Enclosure-specific hot-spares
-
Intelligent Drive Handling:
-
In degraded mode: skips irreparable blocks to continue rebuild
-
In normal operation: data-block verification and repair
Host Interface
-
Four (4) out of the six (6) 4G FC channels per controller
-
32Gbps bandwidth via separate host ports from individual controllers
-
Hot-swappable I/O modules
-
Concurrent I/O commands
-
Tagged command queuing up to 1024
-
Max. command queue up to 1024
-
Fault-tolerant host links via external FC switches or the onboard hub
Drive Interface
-
Two (2 - default) or four (4 – manual) in dual-loops to F16F series FC drive enclosures and A16F Series SATA drive enclosures
-
Two (2 – R4030) or one (1 – S4030) SAS ports (SFF-8470) to S16S series drive enclosures (using SATA-II disk drives)
-
S.M.A.R.T. support
-
Automatic bad-sector reassignment
-
Intelligent loop switched access fairness dual-loop
-
SES enclosure service support through the drive loops
System Components
-
Compact 1U enclosure
-
Dual-active/Single- RAID controller configurations
-
Fault-tolerant modules interfaced through a common backplane
-
One (1) 512MB DDR DIMM per controller (default, supports up to 2GB in size)
-
Redundant, hot-swappable 250W power supply units
-
Redundant, dual-speed cooling modules
-
Hot-swappable I/O modules
-
LCD keypad panel
-
Li-Ion battery backup unit (BBU), life expectancy and charge level aware
Management
-
COM1 serial port for local access to firmware-embedded utility
-
COM2 for UPS connection
-
GUI, Telnet, and SSH system access via an Ethernet port
-
Java-based SANWatch software
-
Management of multiple enclosures via RAID firmware and/or through GUI
-
Firmware-embedded manager via RS-232C (audio jack) that is platform independent
-
Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
-
LCD keypad panel to all configuration options
-
Variable logical drive options per DIMM size
-
Module status LED indicators:
-
Seven (7) per controller module
-
One (1) per power supply unit
-
One (1) per BBU module
-
Two (2) per cooling module
-
Three (3) per LCD panel
-
Two (2) per Ethernet port
-
Two (2) per Fibre port on I/O module
-
Presence detect & thermal sensors via I²C bus (via SES with drive enclosures)
Physical/Electrical
Interfaces
-
Twelve (12) Fibre SFP ports on individual I/O modules, with onboard hub
-
Two (2 – R4030) or one (1 – S4030) SAS wide ports (SFF-8470 Infiniband type)
-
One (1) Fast Ethernet management port (per controller)
-
Two (2) serial COM ports (per controller)
Power Supply Module
Redundant hot-swappable power supplies with PFC
Input |
100VAC at 5A, 240VAC at 2.5A with PFC (auto-switching) |
47 to 63Hz |
Output |
(Maximum output: 250 Watts) |
+12.0V |
16A max. |
+ 5.0V |
25A max. |
+ 3.3V |
20A max |
Dimensions |
265 (D) x 106 (W) x 40 (H) mm (10.43 x 4.17 x 1.57 inches) |
Cooling Module
Redundant dual-thermal-fan cooling modules
Maximum Air Flow |
-
High speed: 31.8 CFM
-
Low speed: 20.1 CFM
|
Environmental Specifications
Temperature |
-
Operating: 0º to 35ºC or 0º to 40ºC (32º F to 104º F without BBU)
-
Non-operating: -40º to 60ºC (-40º F to 149º F)
|
Relative humidity |
Non-condensing : 5% to 95% |
Altitude |
-
Operating: 0 to 3,658m (12,000 ft)
-
Non-operating: 0 to 12,192m (40,000 ft)
|
Dimensions
Dimensions |
With Front Handles |
Height |
43.5mm (1.7 inches) |
Width |
442mm (17.4 inches) |
Length |
540mm (21.3 inches) |
Package: 18(H) x 59(W) x 72(D) cm (7.1 x 23.2 x 28.3 inches) |
System weight
-
Net weight: 10kg (22 pounds)
-
Gross weight: 11.5kg (25.3 pounds)