						SAS to SAS RAID subsystem
 
					- 
						Redundant or single RAID controller
 
					- 
						EonPath® multi-pathing, load-balancing software
 
					- 
						4 or 2 SAS 4x wide host ports
 
					- 
						Hardware RAID6 engine by dedicated ASIC400 chipsets
 
					- 
						Superior performance w/ uncomplicated connectivity
 
					- 
						16 SAS disk drives
 
					- 
						Expansion to 80TB via a 4x wide expansion port
 
					- 
						Corresponding JBODs: S16S-J1000-R (dual-controller); S16S-J1000-S (single-controller)
 
				
				
					
						
							| 
								Model | 
							
								Host Interface | 
							
								Drive Interface | 
							
								Controller | 
							
								Form Factor | 
						
					
					
						
							| 
								S16S-G1030 | 
							
								2 multi-lane wide ports (SFF-8470) | 
							
								SAS | 
							
								Single | 
							
								3U rack-mount | 
						
					
				
				
					Corresponding JBODs
				
					- 
						Hardware RAID parity computing
 
				
				
					
						
							| 
								RAID | 
							
								JBOD | 
							
								Max. number | 
						
					
					
						
							| 
								S16S-G1030 | 
							
								S16S-J1000-S | 
							
								4 | 
						
					
				
				
					Information about supported disk drives, network components, and software compatibility, please refer to our VIPRoom website (for authorized dealers).
			 
			
				
					RAID
				
					- 
						Hardware RAID5 & RAID6
 
					- 
						Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID
 
					- 
						RAID Migration
 
					- 
						Configurable stripe size and write policy per array
 
					- 
						Multiple Global, Dedicated, & Enclosure-specific hot-spares
 
					- 
						Intelligent Drive Handling:
						
							- 
								In degraded mode: skips irreparable blocks to continue rebuild
 
							- 
								In normal operation: data-block verification and repair
 
						
					 
				
				
					Host Interface
				
					- 
						4 (S16S-R1030) or 2 (S16S-G1030) SAS wide ports
 
					- 
						12Gbps bandwidth (half duplex) per port
 
					- 
						Concurrent I/O commands
 
					- 
						Tagged command queuing up to 1024
 
					- 
						Max. command queue up to 1024
 
					- 
						Fault-tolerant host links with the EonPath multi-pathing software
 
				
				
					Drive Interface
				
					- 
						16 3.0Gbps SAS, hot-swappable drive trays
 
					- 
						Accommodates 1-inch pitch, 3.5-inch SAS disk drives
 
					- 
						S.M.A.R.T. and NCQ support
 
					- 
						Automatic bad-sector reassignment
 
					- 
						Dedicated bandwidth to each connected drive
 
					- 
						In-band enclosure service through the expansion links from expansion enclosures
 
					- 
						Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
 
					- 
						MUX kits with port selectors for dual-controller access to SATA drives
 
				
				
					System Components
				
					- 
						High density, smartly managed 3U enclosure
 
					- 
						Dual redundant or single RAID controller
 
					- 
						One DIMM module with capacities from 512MB to 2GB
 
					- 
						Redundant, hot-swappable 530W power supply units
 
					- 
						Redundant, dual-speed cooling modules 
 
					- 
						Sixteen (16), hot-swappable drive trays
 
					- 
						Two (2) forearm handles
 
					- 
						Li-Ion battery backup unit (BBU), life expectancy and charge level aware
 
				
				
					Management
				
					- 
						COM1 serial port for local access to firmware-embedded utility
 
					- 
						COM2 for UPS connection
 
					- 
						Automated cache flush and caching mode operation per enclosure status
 
					- 
						GUI, Telnet, and SSH system monitoring via Ethernet
 
					- 
						Java-based SANWatch software
 
					- 
						Firmware-embedded manager via RS-232C (audio jack) that is platform independent
 
					- 
						Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
 
					- 
						LCD keypad panel for monitoring and access to all configuration options
 
					- 
						Variable logical drive options per DIMM size
 
					- 
						Module status LED indicators:
						
							- 
								Two (2) per drive tray
 
							- 
								Seven (7) per controller module
 
							- 
								One (1) per power supply unit
 
							- 
								One (1) per BBU module
 
							- 
								Two (2) per cooling module
 
						
					 
				
				
					- 
						Presence detection & thermal sensors via I2C bus
 
				
				
					Power Supply Module
				
					Redundant hot-swappable power supplies with PFC
				
					
						
							| 
								Input | 
							
								100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching) | 
						
						
							| 
								47 to 63Hz | 
						
						
							| 
								Output | 
							
								(Maximum output: 530 Watts) | 
						
						
							| 
								+12.0V | 
							
								32A max. | 
						
						
							| 
								+ 5.0V | 
							
								32A max. | 
						
						
							| 
								+3.3V | 
							
								30A max. | 
						
					
				
				
					Cooling Module
				
					Redundant dual-thermal-fan cooling modules
				
					
						
							| 
								Maximum air flow | 
							
								90CFM (high speed); 
								70.7CFM (low speed) | 
						
					
				
				
					Environmental Specifications
				
					
						
							| 
								Operating temperature: | 
							
								5º to 40ºC  (35°C if battery is applied) | 
						
						
							| 
								Non-operating temperature: | 
							
								- 40º to 60ºC | 
						
						
							| 
								Relative humidity: | 
							
								5 to 95%, non-condensing | 
						
						
							| 
								Operating altitude: | 
							
								Operating: 0 to 12,000 ft | 
						
					
				
				
					Dimensions
				
					- 
						Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
 
				
				
					System Weight
				
					- 
						Net weight: 28.5kg (62.7 pounds)
 
					- 
						Gross weight: 30.5kg (67.1 pounds)